Bio Instruments S.R.L.
Phyto-Sensor Group

Connecting People and Plants

  • English
  • Русский
  • Home
    • News
  • Products
    • PTM-48A Photosynthesis Monitor
      • Overview
      • Basic configuration
      • Specifications
      • Partitioning of CO2 exchange
      • Stomatal conductance monitoring
      • Software
      • Documentation
      • Literature and References
      • Sensors
    • PM-11 Phytomonitor
      • Overview
      • Specifications
      • Communication options
      • Mounting options
      • Recommended assemblies
      • Documentation
      • Software
      • Sensors
    • Sensors for PTM-48A and PM-11
      • Overview
      • Plant Sensors
        • SD-5P, SD-6P Stem Micro-Variation sensors
        • DE-1P Dendrometer
        • FI-LP, FI-MP, FI-SP Fruit Growth sensors
        • FI-XSP Extra Small Fruit Growth sensor
        • LT-1P Leaf Temperature sensor
        • LT-IRP Infrared Leaf Temperature sensor
        • SF-4P, SF-5P Sap Flow sensors
        • SA-20P Auxanometer
      • Environmental Sensors
        • PIR-1P Quantum sensor
        • TIR-4P Pyranometer
        • SMS-5P Soil Moisture sensor
        • LWS-02P Leaf Wetness sensor
        • ST-21P Soil Temperature sensor
        • SMTE Soil Moisture, Temperature, EC sensor
        • RTH-11 Meter and RTH-48 Meter
    • Sensors for third party loggers
      • Overview
      • Plant Sensors
        • SD-5M, SD-6M Stem Micro-Variation sensors
        • DE-1M Dendrometer
        • FI-LM, FI-MM, FI-SM Fruit Growth sensors
        • FI-XSM Extra Small Fruit Growth sensor
        • LT-1M Leaf Temperature sensor
        • SF-4M, SF-5M Sap Flow sensors
        • SA-20M Auxanometer
      • Environmental Sensors
        • PIR-1M Quantum sensor
        • TIR-4M Pyranometer
        • SMS-5M Soil Moisture sensor
        • ST-21M Soil Temperature sensor
  • Documentation
  • About
  • PTM-48A Photosynthesis Monitor
    • Overview
    • Basic configuration
    • Specifications
    • Partitioning of CO2 exchange
    • Stomatal conductance monitoring
    • Software
    • Documentation
    • Literature and References
    • Sensors
  • PM-11 Phytomonitor
    • Overview
    • Specifications
    • Communication options
    • Mounting options
    • Recommended assemblies
    • Documentation
    • Software
    • Sensors
  • Sensors for PTM-48A and PM-11
    • Overview
    • Plant Sensors
      • SD-5P, SD-6P Stem Micro-Variation sensors
      • DE-1P Dendrometer
      • FI-LP, FI-MP, FI-SP Fruit Growth sensors
      • FI-XSP Extra Small Fruit Growth sensor
      • LT-1P Leaf Temperature sensor
      • LT-IRP Infrared Leaf Temperature sensor
      • SF-4P, SF-5P Sap Flow sensors
      • SA-20P Auxanometer
    • Environmental Sensors
      • PIR-1P Quantum sensor
      • TIR-4P Pyranometer
      • SMS-5P Soil Moisture sensor
      • LWS-02P Leaf Wetness sensor
      • ST-21P Soil Temperature sensor
      • SMTE Soil Moisture, Temperature, EC sensor
      • RTH-11 Meter and RTH-48 Meter
  • Sensors for third party loggers
    • Overview
    • Plant Sensors
      • SD-5M, SD-6M Stem Micro-Variation sensors
      • DE-1M Dendrometer
      • FI-LM, FI-MM, FI-SM Fruit Growth sensors
      • FI-XSM Extra Small Fruit Growth sensor
      • LT-1M Leaf Temperature sensor
      • SF-4M, SF-5M Sap Flow sensors
      • SA-20M Auxanometer
    • Environmental Sensors
      • PIR-1M Quantum sensor
      • TIR-4M Pyranometer
      • SMS-5M Soil Moisture sensor
      • ST-21M Soil Temperature sensor
TIR-4P Pyranometer
for PM-11for PTM-48A

TIR-4P Pyranometer

Overview

The TIR-4P Pyranometer measures total irradiance in Watts per square meter. The pyranometer includes a temperature compensated silicon detector equipped with the cosine-correcting head.

The spectral response of TIR-4P Pyranometer does not cover the full range of solar spectrum. Therefore, it should be used under the same conditions as at calibration. All TIR-4P sensors are calibrated against LI-200SA Pyranometer (LI-COR, USA) under natural, unobstructed daylight conditions.

Standard output cable length is 4 meters.

Specifications

CalibrationNatural sunlight,
Against LI-200SA Pyranometer
Measurement range0 to 1000 W/m2
Absolute accuracy±10%
Repeatability±1%
Dimensions, mm110 L × 20 ∅
Mass without cable30 g
Output cable length4  m

Documentation

TIR-4P Pyranometer Datasheet

See also:

  • PM-11 Phytomonitor
  • PTM-48A Photosynthesis Monitor
  • PIR-1P Quantum sensor
http://Phyto-Sensor.com
© 2010 Phyto-Sensor Group