Bio Instruments S.R.L.
Phyto-Sensor Group

Connecting People and Plants

  • English
  • Русский
  • Home
    • News
  • Products
    • PTM-48A Photosynthesis Monitor
      • Overview
      • Basic configuration
      • Specifications
      • Partitioning of CO2 exchange
      • Stomatal conductance monitoring
      • Software
      • Documentation
      • Literature and References
      • Sensors
    • PM-11 Phytomonitor
      • Overview
      • Specifications
      • Communication options
      • Mounting options
      • Recommended assemblies
      • Documentation
      • Software
      • Sensors
    • Sensors for PTM-48A and PM-11
      • Overview
      • Plant Sensors
        • SD-5P, SD-6P Stem Micro-Variation sensors
        • DE-1P Dendrometer
        • FI-LP, FI-MP, FI-SP Fruit Growth sensors
        • FI-XSP Extra Small Fruit Growth sensor
        • LT-1P Leaf Temperature sensor
        • LT-IRP Infrared Leaf Temperature sensor
        • SF-4P, SF-5P Sap Flow sensors
        • SA-20P Auxanometer
      • Environmental Sensors
        • PIR-1P Quantum sensor
        • TIR-4P Pyranometer
        • SMS-5P Soil Moisture sensor
        • LWS-02P Leaf Wetness sensor
        • ST-21P Soil Temperature sensor
        • SMTE Soil Moisture, Temperature, EC sensor
        • RTH-11 Meter and RTH-48 Meter
    • Sensors for third party loggers
      • Overview
      • Plant Sensors
        • SD-5M, SD-6M Stem Micro-Variation sensors
        • DE-1M Dendrometer
        • FI-LM, FI-MM, FI-SM Fruit Growth sensors
        • FI-XSM Extra Small Fruit Growth sensor
        • LT-1M Leaf Temperature sensor
        • SF-4M, SF-5M Sap Flow sensors
        • SA-20M Auxanometer
      • Environmental Sensors
        • PIR-1M Quantum sensor
        • TIR-4M Pyranometer
        • SMS-5M Soil Moisture sensor
        • ST-21M Soil Temperature sensor
  • Documentation
  • About
  • PTM-48A Photosynthesis Monitor
    • Overview
    • Basic configuration
    • Specifications
    • Partitioning of CO2 exchange
    • Stomatal conductance monitoring
    • Software
    • Documentation
    • Literature and References
    • Sensors
  • PM-11 Phytomonitor
    • Overview
    • Specifications
    • Communication options
    • Mounting options
    • Recommended assemblies
    • Documentation
    • Software
    • Sensors
  • Sensors for PTM-48A and PM-11
    • Overview
    • Plant Sensors
      • SD-5P, SD-6P Stem Micro-Variation sensors
      • DE-1P Dendrometer
      • FI-LP, FI-MP, FI-SP Fruit Growth sensors
      • FI-XSP Extra Small Fruit Growth sensor
      • LT-1P Leaf Temperature sensor
      • LT-IRP Infrared Leaf Temperature sensor
      • SF-4P, SF-5P Sap Flow sensors
      • SA-20P Auxanometer
    • Environmental Sensors
      • PIR-1P Quantum sensor
      • TIR-4P Pyranometer
      • SMS-5P Soil Moisture sensor
      • LWS-02P Leaf Wetness sensor
      • ST-21P Soil Temperature sensor
      • SMTE Soil Moisture, Temperature, EC sensor
      • RTH-11 Meter and RTH-48 Meter
  • Sensors for third party loggers
    • Overview
    • Plant Sensors
      • SD-5M, SD-6M Stem Micro-Variation sensors
      • DE-1M Dendrometer
      • FI-LM, FI-MM, FI-SM Fruit Growth sensors
      • FI-XSM Extra Small Fruit Growth sensor
      • LT-1M Leaf Temperature sensor
      • SF-4M, SF-5M Sap Flow sensors
      • SA-20M Auxanometer
    • Environmental Sensors
      • PIR-1M Quantum sensor
      • TIR-4M Pyranometer
      • SMS-5M Soil Moisture sensor
      • ST-21M Soil Temperature sensor
PIR-1P Quantum Sensor measures Photosynthetic Photon Flux (PPF)
PIR-1P Quantum Sensor measures Photosynthetic Photon Flux (PPF) calibration
for PM-11for PTM-48A

PIR-1P Quantum sensor

Overview

The PIR-1P Quantum Sensor measures Photosynthetic Photon Flux (PPF) in µmol·m−2·s−1. The sensor is cosine-corrected, and has a domed diffusion disk and head for improved self-cleaning characteristics and long-term stability. The cosine error for typical applications is less than 2%. The output increases approximately 1% per year because of changes in the optical transparency of the diffusion disk. Quantum sensor is calibrated for sunlight. Average spectral errors associated with different light sources is shown on the right.

Standard output cable length between signal conditioner and monitor is 3 meters.

Specifications

CalibrationNatural sunlight
Measurement range0 to 2500 µmol·m−2·s−1
Absolute accuracy±5%
Repeatability±1%
Operating temperature0 to 50 ℃
Protection index of sensorIP 67
Sensor dimensions, mm24 ∅ × 27.5 H
Output cable length3  m

Documentation

PIR-1P Quantum Sensor Datasheet

See also:

  • PM-11 Phytomonitor
  • PTM-48A Photosynthesis Monitor
  • TIR-4P Pyranometer
http://Phyto-Sensor.com